Torlon® 4275
  

TYPICAL PROPERTIES OF Torlon® 4275
    Typical Values(1)
   Test  U.S. Customary Units SI Units
Property Method(2)   Value  Units Value  Units
Mechanical
Tensile strength    
    73°F (23°C) D 1708   22.0  kpsi    152 MPa 
    275°F (135°C) D 1708   16.9  kpsi    113 MPa 
    450°F (232°C) D 1708   8.1  kpsi    56 MPa 
    -321°F (-196°C) D 1708   18.8  kpsi    130 MPa 
Tensile elongation    
    73°F (23°C) D 1708     7
    275°F (135°C) D 1708   15    15
    450°F (232°C) D 1708   17    17
    -321°F (-196°C) D 1708     3
Tensile modulus D 1708   1130  kpsi    7.8 GPa 
Flexural strength    
    73°F (23°C) D 790   30.2  kpsi    212 MPa 
    275°F (135°C) D 790   22.4  kpsi    157 MPa 
    450°F (232°C) D 790   15.8  kpsi    111 MPa 
    -321°F (-196°C) D 790   29.0  kpsi    203 MPa 
Flexural modulus    
    73°F (23°C) D 790   1060  kpsi    7.3 GPa 
    275°F (135°C) D 790   810  kpsi    5.6 GPa 
    450°F (232°C) D 790   740  kpsi    5.1 GPa 
    -321°F (-196°C) D 790   1390  kpsi    9.6 GPa 
Izod impact strength    
    Notched D 256   1.6  ft-lb/in    84 J/m 
    Unnotched D 256   4.7  ft-lb/in    250 J/m 
Shear strength D 732   11.1  kpsi    77 MPa 
Compressive strength D 695   17.8  kpsi    120 MPa 
Compressive modulus D 695   580  kpsi     
Poisson's ratio   0.39      0.39  
Thermal
Heat deflection temperature    
    at 264 psi (1.82 MPa) D 648   536  °F    280 °C 
Flammability Rating(3) UL-94   94 V-0      94 V-0  
Coefficient of thermal expansion D 696   14  10-6 in/in/°F    25.2 10-6 m/m/°C 
Oxygen index D 2863   45    45
Electrical
Dielectric constant    
    at 1 kHz D 150   7.3      7.3  
    at 1 MHz D 150   6.6      6.6  
Dissipation factor    
    at 1 kHz D 150   0.059      0.059  
    at 1 MHz D 150   0.063      0.063  
Surface resistivity D 257   4x1017  ohm    4x1017 ohm 
Volume resistivity D 257   3x1015  ohm-in    8x1013 ohm-m 
General
Moisture absorption D 570   0.33    0.33
Rockwell hardness D 785   70      70  
Density D 1505   0.054  lb/in3    1.51 g/cm3 
 
1Actual properties of individual batches will vary within specification limits.
2Test methods are ASTM unless otherwise noted.
3These flammability ratings are not intended to reflect hazards presented by these or any other materials under actual fire conditions.